- EFEKTIVNÍ
Communication | IO-Link |
Number of ejectors | 8 |
Ejector type 1 | SCPSt 15 G02 NO |
Product key | SCTSi-IOL-8-AB-8C7A |
Variety, optimization of production processes, and continuous energy and process control are the challenges of the future. In order to meet these demands, powerful, flexible and energy-efficient vacuum systems are required. The answer is our Compact Terminal SCTSi IO-Link, a compact unit of several vacuum generators for simultaneously and independently handling different parts with a single vacuum system.
Central compressed air and power supply for up to 16 ejectors
Direct connection to the controller via only one data line
Modular design with different, individually controllable vacuum circuits for handling different workpieces
Easy configurability of process and device parameters via IO-Link or NFC
Reduction of compressed air consumption by up to 80 % thanks to automatic air saving function
Your Individual Configuration
The compact terminals SCTSi offer the flexibility to design the handling process entirely according to your needs. Thanks to innovative configurators, our sales staff can create a custom-made solution for you in no time at all.
In addition to an offer for your individual product, you will also receive a CAD model.
Request your personal configuration now and contact us!
Kód produktu
Kód produktu se podobně jako číslo dílu používá k jednoznačné identifikaci konfigurací produktů společnosti Schmalz. Kód výrobku lze nalézt na štítku výrobku nebo na nabídce či objednávce. Máte dotazy k výrobku nebo si chcete znovu objednat konfiguraci? Pak si prosím připravte tento klíč, až budete kontaktovat společnost Schmalz.
Code | Type |
---|---|
SCTSI | SCTSi |
Code | Type |
---|---|
IOL | IO-Link |
Code | Type |
---|---|
E + number | Number of ejectors |
V + number | Number of valves |
E + number V + number | Number of ejectors and number of valves |
Code | Type |
---|---|
I + number | Number of IO-Link modules |
D + number | Number of digital modules |
I + number V + number | Number of IO-Link and digital modules |
Code | Type |
---|---|
ABC00001C | Individual configuration code |
Informace o objednávce
Variant | Type |
---|---|
SCTSi-IOL | Main body SCTSi IO-Link |
Variant | Type |
---|---|
1-16 | Number of ejectors |
Note:
A number of 16 ejectors can be integrated in one terminal.
Variant | Type |
---|---|
AA | Standard version, push-in vacuum connection, hose outer diameter = 6 mm (for nozzle size = 0.7 mm and 1.0 mm) or hose outer diameter = 8 mm ( for nozzle size = 1.5 mm) |
AB | Standard version, threaded connection G1/8"-F (for all nozzle sizes) |
Variant | Type | Option of terminal | Suction rate l/min | Air consumption l/min | Part no. |
---|---|---|---|---|---|
C8B | SCPst 07 GS01 NC C8B | AA | 16 | 22 | 10.02.02.05957 |
C79 | SCPSt 07 GS01 NO C79 | AA | 16 | 22 | 10.02.02.05954 |
C8N | SCPSt 10 GS01 NC C8N | AA | 36 | 46 | 10.02.02.05984 |
C8A | SCPSt 10 GS01 NO C8A | AA | 36 | 46 | 10.02.02.05956 |
C7U | SCPSt 15 GS02 NC C7U | AA | 65,5 | 98,5 | 10.02.02.06203 |
C78 | SCPSt 15 GS02 NO C78 | AA | 65,5 | 98,5 | 10.02.02.06202 |
C7E | SCPSt 07 G02 NC C7E | AB | 16 | 22 | 10.02.02.06187 |
C7H | SCPSt 07 G02 NO C7H | AB | 16 | 22 | 10.02.02.06184 |
C7D | SCPSt 10 G02 NC C7D | AB | 36 | 46 | 10.02.02.06188 |
C7B | SCPSt 10 G02 NO C7B | AB | 36 | 46 | 10.02.02.06185 |
C7N | SCPSt 15 G02 NC C7N | AB | 65,5 | 98,5 | 10.02.02.06189 |
C7A | SCPSt 15 G02 NO C7A | AB | 65,5 | 98,5 | 10.02.02.06186 |
Note:
You can choose between different nozzle Technologies and sizes, connections or rest positions for the suction Valve (NO/NC/IMP).
A maximum of 4 different ejector blocks are possible.
From 9 ejectors upwards, a larger hose Diameter is required for compressed air supply.
Type | Operating temperature [°C] |
Pressure range (operating pressure) [bar] |
Electrical connection | Communication |
---|---|---|---|---|
SCTSi IO-Link | 0...50 | 2...6 | M12, 5-pin plug | IO-Link class B |
Type | Nozzle Size [mm] |
Degree of evacuation [%]* |
Max. suction rate [m³/h]* |
Max. suction rate [l/min]* |
Vacuum air consumption [m³/h]* |
Air consumption for blow off [m³/h]* |
Sound level free* [dB(A)]** |
Sound level during gripping* [dB(A)]** |
---|---|---|---|---|---|---|---|---|
SCPSt 07... | 07 | 85 | 0.98 | 16.0 | 1.35 | 7.25 | 63 | 58 |
SCPSt 10... | 10 | 85 | 2.21 | 36.0 | 2.85 | 7.25 | 73 | 60 |
SCPSt 15... | 15 | 85 | 4.03 | 65.5 | 6.03 | 7.25 | 73 | 65 |
SCPSt 2-07... | 2-07 | 85 | 2.28 | 37.0 | 1.35 | 7.25 | 63 | 58 |
SCPSt 2-09... | 2-09 | 85 | 3.05 | 49.5 | 2.49 | 7.25 | 73 | 60 |
SCPSt 2-14... | 2-14 | 85 | 4.40 | 71.5 | 5.04 | 7.25 | 75 | 65 |
*At optimal operating pressure (4 bar)
**No linear increase in sound level with increase in ejector disks
V této části naleznete odpovídající dokumentaci k tomuto výrobku.
Dokumenty | Jazyk |
---|---|
Česky | |
Česky |
Dokumentace je plně k dispozici také v angličtině.
Dokumenty | Jazyk |
---|---|
Angličtina | |
Angličtina | |
Angličtina |
V této části naleznete odpovídající software pro tento produkt.
Software | Jazyk |
---|---|
Angličtina | |
Angličtina |
Near-Field Communication (NFC)
Networking in Industry 4.0 Systems
Automatic Air Saving Function
Integrated Electronic Sub-Bus System
Eco-Nozzle Technology
(1) Connection of SCTSI via IO-Link master
(2) Connection SCTSi via Profinet / EtherCAT / Ethernet/IP
Communication | IO-Link |
Number of ejectors | 8 |
Ejector type 1 | SCPSt 15 G02 NO |
Product key | SCTSi-IOL-8-AB-8C7A |
Communication | IO-Link |
Number of ejectors | 8 |
Ejector type 1 | SCTSi 15 G02 NC |
Product key | SCTSi-IOL-8-AB-8C7N |
Communication | IO-Link |
Number of ejectors | 4 |
Ejector type 1 | SCPSt 15 G02 NC |
Product key | SCTSi-IOL-4-AB-4C7N |
Communication | IO-Link |
Number of ejectors | 4 |
Ejector type 1 | SCPSt 15 G02 NO |
Product key | SCTSi-IOL-4-AB-4C7A |