FA-X / FA-M Error handling
| DataDictionary | Number (new) | Error number old |
Text Display | Possible cause | Solution | |||
| 130 | 0x0082 | Bit 0 | Internal error: data corruption | Error 001 | E01 | Internal error: data corruption | Supply voltage was disconnected too quickly after a parameter change; save process was not fully completed. | Clear the error by restoring the factory setting with the [rE5] function or parameter. Use engineering tool to import a valid dataset. If the error [E01] occurs again after you reactivate the supply voltages, contact Schmalz Service. |
| 130 | 0x0082 | Bit 2 | Supply voltage too low | Error 003 | E07 | Primary voltage too low | Sensor supply voltage is too low. | Check power supply unit and power load. Increase supply voltage |
| 130 | 0x0082 | Bit 3 | Supply voltage too high | Error 004 | E17 | Primary voltage too high | Sensor supply voltage is too high. | Check power supply unit. Reduce supply voltage |
| 130 | 0x0082 | Bit 6 | Short circuit at OUT2 | Error 007 | Short circuit at OUT2 | Short circuit at OUT2. | Check OUT2. | |
| 130 | 0x0082 | Bit 10 | Vacuum Sensor calibration failed | Error 011 | E03 | Vacuum sensor calibration failed | Zero-point adjustment for vacuum sensor is outside of the tolerance 3% FS. Calibration was canceled when measurement value was too high or too low. | Vent the vacuum circuit. Calibrate the vacuum sensor again. |
| 130 | 0x0082 | Bit 11 | Pressure Sensor calibration failed | Error 012 | Pressure sensor calibration failed | Zero-point adjustment for pressure sensor is outside of the tolerance 3% FS. Calibration was canceled when measurement value was too high or too low. | Vent the vacuum circuit. Calibrate the pressure sensor again. | |
| 130 | 0x0082 | Bit 15 | IO-Link communication interruption | Error 016 | E08 | IO-Link communication abruption | Connection to the master interrupted. | Check connection line. Repeat the power-up process. |
| 146 | 0x0092 | Bit 0 | Valve protection | Warning 001 | Valve protection active | Check the system for leakage. If necessary, adjust “Min. evacuation time” using the process settings. | ||
| 146 | 0x0092 | Bit 1 | Evacuation time above limit | Warning 002 | Evacuation time above limit | Check the system for leakage. If necessary, adjust “Permissible evacuation time t1” using the process settings. | ||
| 146 | 0x0092 | Bit 2 | Leakage rate above limitd | Warning 003 | Leakage above limit | The set leakage rate was exceeded. | Check the system for leakage. If necessary, adjust “Permissible leakage rate” using the process settings. | |
| 146 | 0x0092 | Bit 3 | SP1 not reached in suction cycle | Warning 004 | SP1 not reached in suction cycle | The set switching point was not reached in the last cycle. | Check the system for leakage. If necessary, adjust “SP1” using the process settings. | |
| 146 | 0x0092 | Bit 4 | Free Flow Vacuum over SP2 | Warning 005 | Free flow vacuum over SP2 | During unobstructed suction, the vacuum value is above the parts detection level (SP2). | Check the system for contamination and ensure that the cross sections are appropriate. If necessary, adjust SP2 using the process settings. | |
| 146 | 0x0092 | Bit 5 | Sypply voltage out of operating range | Warning 006 | Primary voltage out of operating range | Supply voltage: outside permissible range. | Check the supply voltage. | |
| 146 | 0x0092 | Bit 8 | Input pressure out of operation range | Warning 009 | Input pressure out of operating range | The input pressure is outside the specified range. | Check the input pressure. | |
| 146 | 0x0092 | Bit 12 | Air saving function limited | Warning 013 | Air saving function limited, less vacuum detected | The air-saving function detects a low vacuum and limits the minimum number of ejectors that can be deactivated. | Check the system for leakage. If necessary, adjust “SP1,” “SP2” or “Min. evacuation time” using the process settings. | |